Protecting against physical and environmental threats
Annex A 7.5 is passed with a dated, site-specific hazard assessment and proportionate safeguards, not with enterprise suppression hardware in a leased office. Cloud hosting shrinks the scope but rarely removes it. Sensors, recurring tickets and roster-tied contact lists make the maintenance evidence assemble itself.
The due-diligence questionnaire asks how you protect your offices from fire, flood and power loss. Your workloads run in AWS, so someone suggests marking ISO 27001 Annex A 7.5 as not applicable. Then the auditor asks to see the comms room.
This guide covers what the control requires, how to run a proportionate hazard assessment, which safeguards suit a leased office, what auditors sample on the walkthrough and how to make the evidence assemble itself. It is written for security officers and operations leads at UK firms of 25 to 250 people who want to pass the audit without buying hardware the building doesn't need.
Our approach treats the dated site assessment as the control and every safeguard as a proportionate response to it. Run that way, the evidence builds up as a by-product of looking after the office, not a folder assembled the week before the audit.
ISO 27001 Annex A 7.5 requires you to assess the physical and environmental hazards at each site, such as fire, flooding, power failure and vandalism, before relying on it. You then fit safeguards proportionate to what the assessment finds and revisit it periodically, so protection keeps pace with change.
The 2022 edition titles the control "Protecting against physical and environmental threats". It is an assess-then-respond exercise, not a hardware shopping list. Where the building actually sits shapes the hazards: near a river, on a flood plain, or somewhere that attracts unrest.
The standard expects the assessment before critical operations depend on a site, with specialist input where the risk justifies it. A new office that will host anything critical therefore gets its assessment before go-live, as a line on the new-site checklist.
The control's classification tells you how to scope it:
The control sits beside equipment siting (A.7.8) and supporting utilities (A.7.11). This one asks what could hit the site; those two ask where kit sits inside the building and what keeps it running.
Rarely. The hyperscaler covers its own data centres, but your office comms room, network uplinks, laptops and paper records remain yours to assess. A short, honest assessment showing the residual scope is small is the defensible answer; a blanket 'not applicable' with no assessment behind it is not.
Most of the environmental risk does sit with AWS or Azure. What stays with you is exactly what this control catches: the comms room where a burst pipe takes out the only link to everything, the on-premises file server under an air-conditioning unit, the paper records a fire turns into a regulatory incident.
Availability failures of this kind hit regulated firms twice. They hurt operationally, and then the regulator and clients ask why single points of failure sat unassessed. Auditors, insurers and enterprise due-diligence teams all put the same question underneath their wording: did anyone actually look at what could take this site out?
A short assessment for a cloud-first firm usually covers four things:
Write down the residual risk and who accepted it. "We assessed it and accepted the residual risk" is a strong answer, while "we never thought about it" is the one that draws a finding.
Run a half-day, site-by-site assessment and record it in your risk register: what is physically at each location, which hazards could plausibly hit it, and the impact. Use free official data, such as the Environment Agency long term flood risk service, to ground the location-specific view. That document becomes the control's backbone.
Work through five steps for each site:
The flood service maps risk from rivers and the sea, surface water, reservoirs and, where data is available, groundwater. It covers England only, so sites in Scotland, Wales or Northern Ireland need their own national service. Whatever the source, the auditor wants location-specific thinking. A generic template that could describe any building won't show it.
Do this after your zoning work under A.7.1 (physical security perimeters) and A.7.3 (securing offices, rooms and facilities) has shown where assets concentrate. The results then feed business continuity planning, because the residual risks you accept here are exactly what continuity arrangements must absorb. At 50-person scale, the remediation it triggers is usually days of work, not weeks.
For a typical leased office the safeguard set is short: landlord-run detection and alarms with evidence held, sensible fire protection for the comms room, kit raised away from water runs, a low-cost leak sensor, and surge-protected UPS power. Gas suppression is rarely proportionate; siting and cheap telemetry usually suffice.
Siting does most of the work. The FedRAMP NIST SP 800-53 Rev. 5 PE-18 Control Catalogue sets the same expectation: position components within the facility to minimise damage from environmental hazards. In a comms room that means nothing critical sits directly beneath pipework or an air-conditioning drip tray.
Check the cheap physical wins first:
Pricing gas suppression before the hazard assessment is guessing with a purchase order.
A rented office whose real exposure is a dripping AC unit needs a shelf higher up and a sensor beneath the unit, not seismic bracing.
Where you genuinely run your own server room, step up. Fit early smoke detection, suppression suitable for an enclosed space with electronics, leak detection under raised floors, and environmental monitoring with alerts. Bring in a fire engineer or facilities consultant rather than improvising. For everyone else, this short list satisfies both the auditor and the enterprise buyer reading your questionnaire answers.
Fire safety wins. Under Article 14 of the Regulatory Reform (Fire Safety) Order 2005, emergency doors must never be locked or fastened so they cannot be opened easily and immediately by anyone needing them. Design access control so people can always get out, and manage the exposure with exit alarms, not locks.
The Regulatory Reform (Fire Safety) Order 2005 (Article 14) goes further than locks. Emergency doors must open in the direction of escape, and sliding or revolving doors cannot serve as dedicated emergency exits. The duty sits with the premises' "responsible person", and auditors check the thinking behind your door design.
A door that fails locked in an evacuation is a finding in two management systems at once: your ISO 27001 audit and your fire risk assessment. That is a worse outcome than the tailgating risk you were trying to prevent.
To keep both sides satisfied:
The anchor evidence is the site hazard assessment showing location-specific thinking, plus the treatment decisions that followed. Around it sit maintenance and inspection records for extinguishers, alarms, UPS and HVAC, sensor output, incident logs, landlord certificates you actually hold, and a Statement of Applicability entry stating how the control is met.
Each item ties back to the assessment:
A landlord's fire certificate you have never seen is an assumption, not evidence.
In shared buildings the landlord's fire-safety and maintenance evidence counts toward the control. Ask for the certificates at a fixed point each year and file them where the auditor can find them, ideally attached to the ticket that tracks the renewal.
Auditors trace your assessment against the real site: they look up in the comms room for pipework you did not mention, check extinguisher and UPS battery service dates, ask what the secure doors do when the alarm sounds, and test whether escalation contact lists still name current staff.
Expect questions like these in the room:
The visit is a sampling exercise, so the weak points show quickly. Three patterns account for most trips:
An alert that routes to someone who left isn't monitoring.
The near-miss question catches firms that never record incidents. A logged burst-pipe scare with a documented change afterwards, such as moving the rack, is stronger evidence than a clean sheet nobody believes.
Automate four things: environmental sensors feeding your existing alerting, maintenance as recurring tickets with attachments, escalation contacts tied to the HR leaver process, and reassessment tasks triggered by office moves or fit-outs. The service history then assembles itself, and lapses surface before the auditor finds them.
Each one replaces a habit that depends on memory:
At this scale the setup is an afternoon of configuration. The payoff arrives when an enterprise buyer or insurer asks for your physical-security evidence and you export it in minutes, with the service history already attached.
| Evidence item | Automated source | Refreshed when |
|---|---|---|
| Site hazard assessment | Risk register entry with a review date | Review cycle, office move, fit-out or near-miss |
| Extinguisher, alarm and UPS servicing | Recurring ticket with certificate attached | Each service date |
| Landlord certificates | Renewal ticket with a named internal owner | Each certificate renewal |
| Environmental readings | Sensor alerts in the monitoring stack | Continuously |
| Escalation contacts | Roster-linked contact list | When HR records a leaver |
Security leadership owns the assessment and the accept-or-treat decisions, while facilities or the landlord operates most of the safeguards. At client scale that usually means a fractional CISO or an operations lead, with the split written down. Name one internal contact for each landlord-run safeguard, so someone is responsible for chasing the certificate.
The 2022 control leans harder on an assess-then-design approach. It also folds in ideas such as designing the environment itself to deter crime and using fire- and water-rated safes as a second line for critical media. If your 2013 documentation was a single risk-register line, the gap to close is a dated, site-specific assessment.
Not for a standard leased office, where a competent internal assessment plus the landlord's evidence is proportionate. Bring one in when the assessment raises something your team cannot judge, such as suppression design for a server room you run, a genuine flood exposure or a structural question. Record why you judged no specialist was needed, because that note is part of the reasoning an auditor will read.
Certification-body practice treats no site hazard assessment at all, where the exposure is severe and obvious, as the absence of a requirement, which grades major. Lapsed maintenance on protective equipment, or an assessment that pre-dates a move, grades minor. Several minors of the same kind can aggregate to a major as a pattern.