VaultISO 27001ISO 27001 Annex A 7.13: equipment maintenance that survives audit
ISO 27001 · A.7.13

ISO 27001 Annex A 7.13: equipment maintenance that survives audit

Equipment maintenance

Harry WestFounder & CEO31 May 202312 min read
Inside This Article
What does ISO 27001 equipment maintenance require under Annex A 7.13?How do you scope ISO 27001 Annex A 7.13 in a cloud-first firm or serviced office?How should you manage engineers who visit to service your equipment?How do you secure remote maintenance sessions and off-site repairs?Do you need a formal maintenance policy document for A.7.13?What does an A.7.13 audit evidence pack contain?What will an auditor ask about equipment maintenance, and how is it graded?How do you automate A.7.13 evidence with service-desk tickets and telemetry?Frequently asked questions
Book a discovery call

Key takeaways

Annex A 7.13 has two faces: keeping equipment and supporting plant serviced on a schedule, and controlling the people and channels that perform maintenance. A cloud-first firm still maintains a short, mostly non-IT list. A simple log, run as service-desk workflow, is the control and the audit evidence.

What the control requires
Annex A 7.13 requires equipment to be maintained so it keeps its security promises, and requires the maintenance activity itself to be authorised, supervised and controlled.
What a cloud-first firm maintains
A cloud-first firm still maintains UPS batteries, comms-room cooling, alarms, extinguishers, office network kit and laptops under warranty. Cloud providers maintain their own data centres, not your comms cupboard.
Engineers and remote access
Visiting engineers count as physical access events needing contracts, NDAs, sign-in and escort. Remote vendor access stays closed by default and opens per session with MFA and logging.
Core audit evidence
The maintenance log is the core evidence, backed by schedules, work orders, escort records, NDAs, service stickers, session logs and custody notes. No freestanding policy document is needed at this scale.

The due-diligence questionnaire asks when your UPS batteries were last replaced and who escorted the engineer who serviced them. Nobody can say, and the certification date slips. This guide to ISO 27001 Annex A 7.13 is for UK regulated service providers and B2B SaaS firms: what the control asks for, how to scope it when you run in the cloud, and the evidence an auditor will read.

It is written for security managers and IT leads who need a working programme in days, not a policy library. You will leave with a short in-scope list, a supervision routine, a remote-access pattern and a way to let your service desk produce the evidence.

What does ISO 27001 equipment maintenance require under Annex A 7.13?

ISO 27001 Annex A 7.13 requires equipment to be maintained so it keeps its security promises, and requires that maintenance itself be controlled. It has two faces: reliability, meaning serviced kit and supporting plant on a schedule with records; and trust, meaning authorised, supervised maintainers, controlled remote access and inspected returns.

The control treats maintenance as a security-sensitive moment, not housekeeping. The engineer with a screwdriver inside your rack can see what is stored there and could alter what runs. Neglect does the same damage more quietly, through the plant nobody owns.

Each face breaks into practices that later sections take in turn:

  • Reliability: service kit to the manufacturer's schedule, log faults and fixes, and include the supporting plant: UPS batteries, cooling, alarms and fire suppression.
  • Trust: allow only authorised maintainers, supervise them on site, authenticate remote sessions and inspect returned devices before they go back to work.

The control is preventive. Planned servicing heads off failure, and the controls around maintainers head off compromise, so neither waits for damage to show. All three security properties are in play: availability for kit that dies from neglect, confidentiality for what a technician can see or take, and integrity for what they could alter or implant.

Two neighbours share the border. Equipment leaving for repair also falls under Annex A 7.9 on off-site assets, and equipment that maintenance condemns exits through Annex A 7.14 on secure disposal. Auditors use ISO 27001 Annex A equipment maintenance as a quick probe of operational ownership: either someone can produce the service schedule or nobody can.

How do you scope ISO 27001 Annex A 7.13 in a cloud-first firm or serviced office?

A cloud-first firm still maintains a short, mostly non-IT list: UPS units and batteries, comms-room cooling, alarms and detectors, extinguishers, office network kit and laptops under warranty. Your cloud provider maintains its data centres, not your comms cupboard. In serviced offices, map which plant the landlord maintains and hold their evidence on file.

Cloud hosting shrinks the list rather than deleting it. A warranty laptop, the switch in the comms cupboard and the extinguisher by the door still age, fail and need a record. The failures that hurt are unglamorous: cooling that cooked the comms room over a bank holiday, or a UPS whose ageing batteries lasted seconds into an outage. "We never maintained it" is a poor sentence in a post-incident report.

For a firm of around 50 people, the inventory usually reads like this:

  • UPS units and batteries, serviced to the manufacturer's interval.
  • Comms-room or cupboard cooling, which tends to fail quietly.
  • Alarms and detectors covering intruder, fire and environmental events.
  • Extinguishers and any suppression system, each with a dated service sticker.
  • Office network kit such as switches, firewalls and access points.
  • Laptops under warranty or repair arrangements, plus any on-premises kit that survives.

Put each item on a schedule driven by the manufacturer's guidance and by how much it would hurt if it failed. Then read your insurance schedule: insurers write maintenance conditions into policies, usually for fire systems and electrical inspection, and claims teams check them. Fold those dates into the same calendar.

This control is about physical equipment and the people who touch it. Software patching and vulnerability management sit in other Annex A controls, so keep them off this calendar and it stays short.

The landlord split is usually clean: the building's systems are theirs, while the UPS under your rack and your own alarm contract are yours. Map it once and file their maintenance confirmations, because their servicing counts for you only if you hold the evidence.

Start the list with the plant, because the servers depend on it.

How should you manage engineers who visit to service your equipment?

Treat every visiting engineer as a physical access event. Use named, authorised suppliers with contracts and NDAs in place before the first visit, sign engineers in, escort and supervise them near racks, patch panels and stored records, and inspect the equipment afterwards for interference. Supervision is not rudeness; it is the control.

Engineer visits borrow the visitor process you already run for physical entry under Annex A 7.2, with extra care near racks and records. Because servicing is scheduled, every visit can be planned and recorded in advance.

An engineer left alone in the server room is an access-control bypass in a hi-vis vest.

A workable routine for each visit:

  1. Authorise the supplier. A named company with a contract and NDA on file before the first visit, not after.
  2. Raise the visit as a ticket. Name the engineer, the task and the areas they will enter.
  3. Sign them in. Use the visitor book or system that reception already runs.
  4. Escort and supervise. Stay with them near racks, patch panels and stored records.
  5. Inspect afterwards. Does the kit behave normally, does the configuration match, are there signs of interference?
  6. Record the result. A two-line inspection note, signed, before the device returns to work.

Escorting feels rude to some teams, so engineers wander unescorted and a service visit turns into an access finding. Give reception a standard line that the rule applies to every visitor. Repaired kit plugged straight back into production has the same flaw: tampering or misconfiguration then surfaces through an incident rather than a checklist.

Free Resource - ISO 27001

The ISO 27001 readiness checklist

Ninety-eight controls mapped to what an assessor actually asks for, in the order they ask it. Written by practitioners who took our ISMS through certification.

AvailablePDF21 pages
  • how to define your ISMS scope
  • the risk-assessment and treatment evidence trail,
  • your Statement of Applicability and residual-risk positions, and
  • the supplier, access-control, and operational-evidence questions most teams miss.

DOC-27001-CHK · v2.4

We'll use your details to give you access to the resource you requested, plus occasional related content. Opt out any time — see our Privacy Notice.

How do you secure remote maintenance sessions and off-site repairs?

Keep vendor remote access closed by default and open it per session with approval, MFA, least privilege, a defined window and a session log. Before data-bearing hardware leaves for repair, back it up, confirm full-disk encryption or pull the drive, and ship it tracked with a chain-of-custody note.

Remote maintenance sessions

A standing, always-on vendor tunnel is the classic quiet hole in an otherwise tidy estate. NIST SP 800-53 Rev. 5 Control MA-4 (Nonlocal Maintenance) expects remote maintenance to be approved and monitored, with strong authentication, detailed records and termination when the session ends. The NCSC Guidance on Third-Party Risks to Operational Technology adds that a third party should reach only the assets specified, and warns that connectivity you have not mapped, such as undisclosed out-of-band channels, can leave you carrying substantial unmanaged risk.

A session runs in five steps:

  1. Request. Raise a ticket with the vendor, the reason and an end time.
  2. Approve. A named internal owner approves, and only then is the account enabled.
  3. Authenticate. Use a named account with MFA, never a shared login, scoped to the specified assets.
  4. Record. Log the session and attach the log to the ticket.
  5. Close. Disable the account at the end time, or sooner when the work finishes.

Shared accounts, missing MFA and sessions nobody logs or reviews are the usual failure pattern. Each step above removes one of them, and the ticket keeps the proof.

Off-site repairs

Data-bearing kit crosses the Annex A 7.9 boundary the moment it leaves. The NCSC Guidance on Secure Sanitisation and Disposal of Storage Media names returning a faulty device to the vendor for repair as one of the moments its sanitisation advice applies. It also notes that on devices encrypted with BitLocker or FileVault, deleting the keys makes the data unreadable.

Run this checklist before dispatch:

  • Back up the data to a location the repair cannot touch.
  • Protect the drive. Pull it, or confirm full-disk encryption such as BitLocker or FileVault is active and the key is not travelling with the device.
  • Paper the repairer. Agree an NDA with the repair shop before the parcel goes.
  • Ship tracked with a chain-of-custody note naming sender, courier and recipient.
  • Inspect on return using the post-repair check from the engineers section.

A laptop shipped with a cleartext disk is a data breach in waiting. If the data is sensitive and none of the protections are possible, a new drive and a destroyed old one is often the economical answer.

Do you need a formal maintenance policy document for A.7.13?

No. At this scale, a maintenance schedule, a simple log and a line in your Statement of Applicability or IT procedures stating who maintains what is a complete answer. Auditors ask for evidence of servicing, not a freestanding policy document, so spend the effort on the calendar and the log.

Standing the programme up takes a day or two: inventory, calendar and supplier paperwork. After that it runs on its own rhythm. Build it alongside the rest of the physical family, once the physical security perimeters under Annex A 7.1 are defined.

The minimum set is four things:

  • An owner. One named person answers the auditor's first question.
  • A calendar. Recurring tickets or diary entries per item.
  • A log. Date, what was found, what was replaced, and who signed it back into service.
  • A line in the SoA or IT procedures saying who maintains what.

A maintenance programme with no log isn't a control. It's an assertion.

Work that happens with nothing written down becomes a shrug at audit and a "the IT guy handles it". Write the log entry when the engineer leaves, while the details are fresh. A few minutes per job is the whole cost.

What does an A.7.13 audit evidence pack contain?

The evidence pack centres on the maintenance log and the schedule it executes, backed by service-desk work orders, visitor and escort records, supplier NDAs and contracts, physical service stickers on extinguishers and UPS units, remote-session authorisations and logs, and custody notes with tracked-shipping records for off-site repairs.

Each artefact proves one thing:

  • Maintenance log and schedule prove servicing was planned and happened: dates, faults, parts and sign-off per asset, against manufacturer-recommended intervals.
  • Service-desk work orders show hardware jobs from request to close.
  • Visitor and escort records show who attended and who accompanied them.
  • Supplier NDAs and contracts show the maintainer was authorised before the first visit.
  • Service stickers on extinguishers and UPS units show the last service date on the asset itself.
  • Remote-session authorisations and logs show who opened access, for how long, and who closed it.
  • Custody notes, tracked-shipping records and the return inspection note show what protected an off-site repair.
  • Landlord confirmations cover the plant that is not yours.

Assemble the pack per asset, not per document type. For the UPS, hold the schedule line, the last log entry, the ticket and a photo of the sticker together, so a single trace answers the auditor's first question.

What will an auditor ask about equipment maintenance, and how is it graded?

Auditors trace a couple of assets from schedule to log to sticker, cross-check one engineer visit against the visitor book and supplier contract, and probe remote routes for MFA and session records. Under certification-body norms, a missing programme or a standing unauthenticated remote channel grades major; lapsed servicing, a missing NDA or an uninspected return grades minor.

Questions to expect in the room:

  • "What is on your maintenance schedule, and who owns it?"
  • "When were the UPS batteries last replaced, and what does the manufacturer say the interval should be?"
  • "Walk me through the last engineer visit: who authorised it, who escorted them, where is the NDA?"
  • "How does your hardware vendor get remote access, and what closes it again afterwards?"
  • "This laptop went for repair in May. Show me what protected the data on it."

On the walk-round the auditor physically reads the extinguisher and UPS tags, so out-of-date stickers surface fast. The follow-through question is a favourite: a fault logged in March, with no entry showing it was fixed.

A fault logged but never closed out is an audit finding waiting for its question.

Unsupervised third-party access to areas holding sensitive data also grades major, because it is the absence of the requirement rather than a lapse in it. Minor lapses aggregate to major when they form a pattern, so remove the pattern rather than patching single records.

Run the trace yourself a month before the audit: two assets, one engineer visit, one remote route, one repair. Every gap you find is a finding you did not receive.

How do you automate A.7.13 evidence with service-desk tickets and telemetry?

Turn the control into workflow: recurring service-desk tickets replace the diary, comms-room sensors and UPS self-tests raise tickets before outages, vendor accounts expire by design, and off-site repair tickets refuse to close without backup, encryption and return-inspection evidence. The closed ticket becomes the log entry, so evidence accrues as the work happens.

Four mappings do the work:

  • Schedule as recurring tickets. Each maintainable asset carries recurring service tickets in the service desk. Overdue services surface on a dashboard instead of in an audit.
  • Telemetry as early warning. Cheap temperature and humidity sensors in the comms room, UPS self-test results and device health alerts feed your monitoring. Degradation becomes a ticket before it becomes an outage.
  • Vendor access that expires. Remote-maintenance accounts stay disabled until an approval workflow enables them with an end time. The approval and the session log land in the same ticket.
  • Repair custody as workflow. An off-site repair ticket asks for backup confirmation, an encryption check, tracking references and the return inspection before it will close.

The human layer shrinks to judgement: who approves a vendor window, whether a battery reading justifies early replacement, what the inspection note says. Everything else is routine the service desk runs.

At this scale, one dashboard answers both the auditor and the enterprise customer's security questionnaire, so evidence stops being a scramble before each review.

TaskManual routineService-desk workflowEvidence it produces
Planned servicingDiary reminder and a spreadsheetRecurring ticket per asset, closed with findingsClosed ticket as the log entry
Comms-room conditionsSomeone notices the heatSensor and UPS self-test alerts raise ticketsAlert history and ticket trail
Vendor remote accessStanding accountAccount enabled by approval with an end timeApproval and session log in one ticket
Off-site repairEmail and a courier slipTicket that will not close without backup, encryption check, tracking and inspectionCustody trail and inspection note

Frequently asked questions

Treat it as mandatory in practice, because it is the artefact every auditor asks for and the only way to show servicing was planned rather than improvised. A spreadsheet is enough at small scale. If you have no history, start the log from today and attach invoices or service certificates for earlier work rather than reconstructing entries.

Yes, once you rely on them for work. The case to plan for is the warranty swap, where the vendor replaces the device and keeps the faulty one, so its drive never comes back. Encrypt or remove the drive before dispatch, record the swap in the log and update the asset register with the replacement's serial number.

Annex A 7.9 protects the asset while it is away from your premises, and A.7.13 governs the repair itself. One ticket can serve both: record who holds the device, where it is and when it is due back. A repair that overruns its return date is the trigger to chase the repairer and, if the disk was not encrypted, to assess whether data is at risk.

It leaves through secure disposal under Annex A 7.14. Before it goes, record the fault and the decision to condemn in the maintenance log, update the asset register and confirm any storage media is sanitised or destroyed. Keep the disposal certificate with the log entry so the equipment's history closes in one place.

Yes, and a missed date can complicate a claim. Ask your broker for the conditions in writing rather than relying on memory of the policy, copy every date into the calendar and file the inspection certificate against each entry. Settle the question before an incident, not during a claim.

Profile image for Harry West, Founder and CEO of GRCMANA
Author

Harry West

Harry is the founder of GRCMANA, he helps regulated service providers close the enterprise trust gap — turning GRC, cyber resilience and AI governance from paperwork exercises into shippable systems.

Standard engine

ISO 27001 reference directory.

Every control in this framework and the clause guides that sit above them, grouped by control domain. Open any entry for its control definition, implementation steps and the audit evidence it expects. Dimmed entries are planned.

ClausesThe management systemClause guides · 23 guides
Clause 4.1Understanding the organization and its context→Clause 4.2Understanding the needs and expectations of interested parties→Clause 4.3Determining the scope of the information security management system→Clause 4.4Information security management system→Clause 5.1Leadership and commitment→Clause 5.2Policy→Clause 5.3Organizational roles, responsibilities and authorities→Clause 6.1Actions to address risks and opportunities→Clause 6.2Information security objectives and planning to achieve them→Clause 7.1Resources→Clause 7.2Competence→Clause 7.3Awareness→Clause 7.4Communication→Clause 7.5Documented information→Clause 8.1Operational planning and control→Clause 8.2Information security risk assessment→Clause 8.3Information security risk treatment→Clause 9.1Monitoring, measurement, analysis and evaluation→Clause 9.2Internal audit→Clause 9.2Preparing for Your ISO 27001 Stage 2 Audit: A Practical Checklist→Clause 9.3Management review→Clause 10.1Continual improvement→Clause 10.2Nonconformity and corrective action→
A.5Organizational Controls37 guides
A.5.1Policies for information security→A.5.2Information security roles and responsibilities→A.5.3Segregation of duties→A.5.4Management responsibilities→A.5.5Contact with authorities→A.5.6Contact with special interest groups→A.5.7Threat intelligence→A.5.8Information security in project management→A.5.9Inventory of information and other associated assets→A.5.10Acceptable use of information and other associated assets→A.5.11Return of assets→A.5.12Classification of information→A.5.13Labelling of information→A.5.14Information transfer→A.5.15Access control→A.5.16Identity management→A.5.17Authentication information→A.5.18Access rights→A.5.19Information security in supplier relationships→A.5.20Addressing information security within supplier agreements→A.5.21Managing information security in the ICT supply chain→A.5.22Monitoring, review and change management of supplier services→A.5.23Information security for use of cloud services→A.5.24Information security incident management planning and preparation→A.5.25Assessment and decision on information security events→A.5.26Response to information security incidents→A.5.27Learning from information security incidents→A.5.28Collection of evidence→A.5.29Information security during disruption→A.5.30ICT readiness for business continuity→A.5.31Legal, statutory, regulatory and contractual requirements→A.5.32Intellectual property rights→A.5.33Protection of records→A.5.34Privacy and protection of PII→A.5.35Independent review of information security→A.5.36Compliance with policies, rules and standards for information security→A.5.37Documented operating procedures→
A.6People Controls8 guides
A.6.1Screening→A.6.2Terms and conditions of employment→A.6.3Information security awareness, education and training→A.6.4Disciplinary process→A.6.5Responsibilities after termination or change of employment→A.6.6Confidentiality or non-disclosure agreements→A.6.7Remote working→A.6.8Information security event reporting→
A.7Physical Controls14 guides
A.7.1Physical security perimeters→A.7.2Physical entry→A.7.3Securing offices, rooms and facilities→A.7.4Physical security monitoring→A.7.5Protecting against physical and environmental threats→A.7.6Working in secure areas→A.7.7Clear desk and clear screen→A.7.8Equipment siting and protection→A.7.9Security of assets off-premises→A.7.10Storage media→A.7.11Supporting utilities→A.7.12Cabling security→A.7.13Equipment maintenance→A.7.14Secure disposal or re-use of equipment→
A.8Technological Controls34 guides
A.8.1User endpoint devices→A.8.2Privileged access rights→A.8.3Information access restriction→A.8.4Access to source code→A.8.5Secure authentication→A.8.6Capacity management→A.8.7Protection against malware→A.8.8Management of technical vulnerabilities→A.8.9Configuration management→A.8.10Information deletion→A.8.11Data masking→A.8.12Data leakage prevention→A.8.13Information backup→A.8.14Redundancy of information processing facilities→A.8.15Logging→A.8.16Monitoring activities→A.8.17Clock synchronization→A.8.18Use of privileged utility programs→A.8.19Installation of software on operational systems→A.8.20Networks security→A.8.21Security of network services→A.8.22Segregation of networks→A.8.23Web filtering→A.8.24Use of cryptography→A.8.25Secure development life cycle→A.8.26Application security requirements→A.8.27Secure system architecture and engineering principles→A.8.28Secure coding→A.8.29Security testing in development and acceptance→A.8.30Outsourced development→A.8.31Separation of development, test and production environments→A.8.32Change management→A.8.33Test information→A.8.34Protection of information systems during audit testing→
OtherAdditional Guides7 guides
GuideISO 27001 Statement of Applicability: what it is, with a worked example→GuideISO 27001 implementation→GuideISO 27001 certification and audit process→GuideISO 27001 mandatory documents and records→GuideISO 27001 gap analysis→GuideISO 27001 certification cost→GuideISO 27001 Annex A controls→
ISO 27001 Accelerator

Ready to accelerate your path to certification?

Work with a Trust Architect to scope your ISMS, close the gaps, and get audit-ready — without stalling your roadmap.

Book a Call →
GRCMANA
  • About
  • Insights
  • Contact
Ask the Trust ArchitectBook a Call →
  • About
  • Insights
  • The Vault
    Compliance VaultCyber Essentials→ISO 27001→SOC 2→ISO 42001→
    Domain VaultGRC Fundamentals→Risk Management→AI Governance→GRC Engineering→
    Other ResourcesFree Tools→Templates→Newsletter→
  • Contact
Book a Call →Ask the Trust ArchitectFixed fee. ISO 27001 in as few as six weeks.
GRCMANA

Helping high-growth B2B tech startups close the Enterprise Trust Gap through security, governance, and AI resilience.

ISO 27001ISO 42001ISO 9001Cyber EssentialsEU AI Act ReadyNIST AI RMF

The Vault

GRC EngineeringAI GovernanceISO 27001ISO 42001All Vault Resources

Resources

BlogFree ToolsTemplatesNewsletter

Company

About GRCMANAContactPrivacy PolicyTerms & ConditionsCookie Policy
© 2025 GRCMANA · All rights reservedRegistered in England & Wales under company registration 16810805. VAT Registration 506308024